1.
Rev. bras. cineantropom. desempenho hum ; 19(1): 108-117, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-843420

ABSTRACT

Abstract Several studies showed that respiratory exchange ratio (RER) have been used as an alternative to evaluate the aerobic capacity in a single incremental test. However, few studies have investigated trained runners. The aim of this study was to verify if the respiratory exchange ratio (RER) could be used as an alternative criterion for estimating anaerobic threshold (AT) in long-distance runners. Nineteen male long-distance runners volunteered to participate in the study. An incremental treadmill test was performed with initial speed of 10 km∙h-1 with increments of 1 km∙h-1 every 1 min until voluntary exhaustion. The variables measured were oxygen uptake (VO2), first and second ventilatory thresholds (VT1 and VT2, respectively), intensity corresponding to RER level of 1.0 (iRER1.0), peak velocity (PV), heart rate (HR), and rate of perceived exertion (RPE). One-way repeated measure analysis variance was used, following Bonferroni post hoc test. Agreement between parameters was evaluated by Pearson correlation and dispersion error. There were no significant differences between iRER1.0 and VT2 parameters. The correlations were significant between iRER1.0 and VT2 parameters for absolute and relative VO2, speed, and HR (r=0.95; r=0.60; r=0.72; r=0.81, respectively). A small mean error (-0.2 km∙h-1) was observed between iRER1.0 and VT2. However, it was also observed an overestimation trend for high speeds. In conclusion, iRER1.0 can be used as an alternative method to detect AT in long distance runners. However, its use is limited in runners with high aerobic capacity.


Resumo Diversos estudos demonstram que a razão de troca respiratória (RER) tem sido utilizada como uma alternativa para estimar a capacidade aeróbia em único teste incremental. No entanto, poucos estudos foram realizados com corredores treinados. Sendo assim, o objetivo do estudo foi avaliar a utilização do RER como uma alternativa para estimar o limiar anaeróbio (AT) em corredores de longa distância. Dezenove corredores de longa distância do sexo masculino participaram do estudo. Foi realizado um teste incremental com velocidade inicial de 10 km∙h-1 com incrementos de 1 km∙h-1 a cada minuto até a exaustão voluntária. As variáveis mensuradas foram consumo de oxigênio (VO2), limiares ventilatórios (VT1 e VT2), intensidade correspondente ao RER no valor igual a 1,0 (iRER1.0), pico de velocidade (PV), frequência cardíaca (HR) e percepção subjetiva de esforço (RPE). Foi realizada a análise de variância de medidas repetidas do tipo one-way, seguido do teste post hoc de Bonferroni. A relação entre as variáveis foi verificada pela correlação de Pearson e a concordância por meio da medida de dispersão dos erros. Não houve diferença significativa entre as variáveis iRER1.0 e VT2. Foram encontradas correlações significativas entre as variáveis iRER1.0 e VT2 para os valores absolutos e relativos de VO2, velocidade e HR (r=0,95; r=0,60; r=0,72; r=0,81, respectivamente). Um pequeno erro médio (-0,2 km∙h-1) foi observado entre iRER1.0 e VT2, bem como uma tendência de superestimação em altas velocidade. Em conclusão, iRER1.0 pode ser utilizado como um método alternativo para detectar o AT em corredores de longa distância, entretanto, seu uso é limitado em corredores com alta capacidade aeróbia.


Subject(s)
Humans , Male , Running/physiology , Anaerobic Threshold , Respiratory Rate
2.
Rev. bras. cineantropom. desempenho hum ; 17(5): 575-582, Sept.-Oct. 2015. tab
Article in English | LILACS | ID: lil-770432

ABSTRACT

Abstract The aim of the present study was to correlate two specific kimono grip strength tests (KGST) with elbow flexors and extensors isokinetic parameters in Jiu Jitsu (JJ) athletes. Fifteen male JJ athletes, from blue to black belt, participated in the study. The two KGST were: maximum static lift (MSL), and maximum number of repetitions (MNR), both gripping a kimono wrapped around a bar. Isokinetic tests consisted of three sets of 5 s elbow flexion-extension maximum voluntary isometric contraction (MVIC) in three different elbow angles (45, 90 and 120°), and two sets of five concentric-eccentric elbow flexion-extension maximum dynamic contractions at 60°∙s-1, to determine peak torque (PT). Absolute values of MSL and MNR were 41.4 ± 16.2 s and 10 ± 5 reps, respectively, and tests presented a nearly perfect correlation among them (r=0.91; p<0.001). Significant correlations were reported between MNR and PT during MVIC for elbow flexors at 45° and 90°, elbow extensors at 120°, and during concentric and eccentric dynamic contractions for both flexors and extensors. Therefore, KGST were highly correlated with isokinetic parameters, and were nearly perfect correlated among them, supporting that one of the tests could be chosen to evaluate strength in JJ athletes. The MNR test presented apparently higher levels of relation than MSL, and provided significant information about muscle strength endurance in JJ athletes.


Resumo O objetivo do presente estudo foi correlacionar dois testes de força (Kimono Grip Strength Tests - KGST) com parâmetros isocinéticos de flexores e extensores do cotovelo em atletas de Jiu Jitsu (JJ). Quinze praticantes do sexo masculino, faixa azul à preta, participaram do estudo. Os dois KGST foram: máximo tempo de sustentação (MTS), e o máximo número de repetições (MNR), ambos com a pegada no kimono enrolado em uma barra fixa. O protocolo isocinético consistiu em três séries de 5 s de contração voluntária isométrica máxima (CVIM) para flexores e extensores do cotovelo, em três ângulos articulares (45, 90 e 120°), e duas séries de cinco contrações dinâmicas no modo concêntrico-excêntrico a 60°∙s-1, para determinação do pico de torque (PT). Os valores absolutos do MTS e MNR foram 41,4 ± 16,2 s e 10 ± 5 repetições, respectivamente, e apresentaram uma correlação quase perfeita (r=0.91; p<0.001). Correlações significativas foram encontradas entre MNR e PT durante a CVIM de flexores a 45° e 90°, extensores a 120° e em contrações concêntricas e excêntricas para flexores e extensores. Portanto, os KGST foram altamente correlacionados com parâmetros isocinéticos, e com correlação quase perfeita entre si, concluindo que apenas um dos testes pode ser utilizado para avaliar força em atletas de JJ. O teste MNR parece apresentar maiores correlações quando comparado ao MTS e fornecer informações significantes sobre força muscular em atletas de JJ.